Elevator C100

Standards 2006/42/EC 2006/94/EC 2004/108/EC
Load capacity 300 Kg / 2 People
Dimensions: height/width/depth 2913/1080/630 mm
Lifting Heights 150m (max.)
Lifting speed 18 m/min
Lifting system Traction cable
Number of steel cables 1 drive cable 1 emergency stop cable 2 guide cables
Cable construction 9mm 4x26ws c SFC B 2160
Supply voltage 3-phases/phases 400 Vac +/-10%
Feeding frequency 50/60 Hz +/-2%
Voltage Control 24 Vdc
Power 3500 W
Machine classification Elevator maintenance of wind turbines
Type of control Top keypad+emergency button
Cabin control panel + emergency button
Electrical main panel + emergency button
End-of-Course Race Two electric: top and bottom
ENGINE Service Three-phase asynchronous
Brake-engine Anti-humidity and anti-corrosion protection
Insulation Class F
Centrifugal brake(tarado) +5% rated speed
Protection IP 55
Load limiter 300 Kg +10%
Service temperature -10 / +50 ºC
Survival temperatures -40 / +55 ªC
Relative humidity in service Max.95% / 40ºC
Height installation above sea level Max. 3.500 m
Cabin construction material aluminium